621 reviews analysed
1. Siemens QF220A Ground Fault Circuit Interrupter, 20 Amp, 2 Pole, 120V, 10,000 Aic,
Description
Testing GFCIs and afcis on a monthly basis is a good idea that is sometimes forgotten. Underwriters laboratories (UL) suggests that afci/GFCI Devices be tested every 30 days after installation to ensure they are properly working. Now the new self test & lockout feature enables the dual function circuit breaker to automatically and continuously test itself to ensure that it is working properly. If it is detected that the device has been compromised, the device trips itself and locks out the homeowner from resetting the device, reducing the possibility of the homeowner incorrectly assuming that the device was tripped to prevent a ground/arc fault. This effortless system guarantees that only the best protection is given to your home at all times.
2. Siemens QF115A Ground Fault Circuit Interrupter, 15 Amp, 1 Pole, 120V, 10,000 AIC
Description
Testing GFCIs and afcis on a monthly basis is a good idea that is sometimes forgotten. Underwriters laboratories (UL) suggests that afci/GFCI Devices be tested every 30 days after installation to ensure they are properly working. Now the new self test & lockout feature enables the dual function circuit breaker to automatically and continuously test itself to ensure that it is working properly. If it is detected that the device has been compromised, the device trips itself and locks out the homeowner from resetting the device, reducing the possibility of the homeowner incorrectly assuming that the device was tripped to prevent a ground/arc fault. This effortless system guarantees that only the best protection is given to your home at all times.
3. Siemens QF220 20-Amp 2 Pole 240-Volt Ground Fault Circuit Interrupter (Discontinued by Manufacturer)
Description
Product Description
Application
GFCIs protect against electrical shock that result from ground faults. Ground faults occur when electrical current in devices stray outside of its normal path. A human body can become part of this circuit, which results in an electrical shock. GFCIs analyze the amount of current entering and existing from the circuit and will trip when the difference is greater than a certain value.
View larger
View larger
Siemens GFCI circuit breakers are UL Listed and CSA Certified as Class A devices. Current imbalances of 4-6 milliamps or more between load conductors will cause the ground fault sensor to trip the circuit Breaker. Note: A load neutral is not required on the circuit. However, the white line neutral (pigtail) must be connected to the panel neutral for the device to function. The Siemens 2-pole GFCI circuit breaker can be installed on a 120/240-volt AC single phase, 3-wire system, the 120/240-volt AC portion of a 240/120-volt, 3-phase, 4-wire system, or on a 208Y/120-volt, 3-phase, 4-wire system. When installed on these systems, protection is provided for 2-wire, 240-volt AC or 208-volt AC circuits; 3-wire, 120/240-volt AC circuits. The Siemens 1-pole GFCI circuit breaker is to be installed only on a single phase 120/240-volt AC system.
Features / Ratings
- Available in 1-pole (15-30 amps) and 2-pole (15-60 amps) through 60 amp rating
- Available in 10 kA and 22 kA (“H”) interrupting rating
- Suitable for a variety of construction applications: spas, hot tubs, kitchens, bathrooms, etc.
- Resists false tripping (shielded to prevent RF interference)
- Standard 1 inch per pole format with plug-in design
- UL Listed and CSA Certified
- Also available in BLF type (low tab bolt-on)
- Provides Class A GFCI protection
- HACR rated
From the Manufacturer
SIEMENS GFCI plug in circuit breakers are intended for use in SIEMENS EQ, SIEMENS Ultimate, ITE, and Gould load centers or meter combinations. The double pole SIEMENS breakers may be used in 1 or 3-phase load centers and are 240V rated. To ensure the warranty on a SIEMENS panel is not voided, the use of SIEMENS breakers is required. The GFCI is intended for areas required by code to have ground fault protection, such as bathrooms, kitchens, and outdoor circuits. Check with your local electrical inspector to confirm. The use of a double pole AFCI allows for shared neutral applications in which two circuits will share a common neutral.
4. Siemens TL137US Talon Temporary Power Outlet Panel with a 20, 30, and 50-Amp Receptacle Installed, Unmetered
Feature
- UL Listed and Outdoor Rated
- Elevated cover with padlock prevents unauthorized use
- Receptacles protected by Siemens circuit breakers
- Surface or pole mount
- UL Listed and Outdoor Rated
- Elevated cover with padlock prevents unauthorized use
- Receptacles protected by Siemens circuit breakers
- Uses Siemens and ElectriCenter RX type hubs
Description
Talon’s line of power outlet panels are designed to meet the demands for temporary power at construction sites and recreational vehicle parks. For construction site applications, power outlet panels are installed for temporary use only until electrical power is available at the site. Recreational Vehicle parks use power outlet panels on a permanent basis as a power source for the RV’s distribution system. A wide variety of configurations are available to address almost any application. Design options include surface (pole mount) and pedestal mount construction, with or without meter socket provisions, and top or bottom feed.
5. UBIZ0250-New Zinsco RC3850 Replacement. Two Pole 50 Amp Thin Series Manufactured by Connecticut Electric.
Feature
- Replacement Zinsco circuit breaker manufactured new by Connecticut Electric
- For use in Zinsco circuit breaker panels
- Intertek ETL Listing to UL Standard 489 for US and Canada-Molded case circuit breakers
- 10,000 AIC
- 50 Amp
- 120/240 VAC 2 Pole breaker in 3/4″ body
- Plug in type
- May also be branded as Sylvania (ie, Sylvania RC 3850)
Description
Product Description
Connecticut Electric manufactures new high quality replacement circuit breakers for Zinsco load centers that accept Zinsco RC style circuit breakers. Circuit breakers should only be replaced with new tested and Safety Agency Listed circuit breakers, never used or refurbished ones.
From the Manufacturer
This 120/240 volt Zinsco 50 amp, double pole, thin series replacement circuit breaker is used in a Zinsco load center. Typical applications, up to 8,800 watts, include electric baseboard heat, fan forced heat and 240 volt air conditioners (up to 23,000 BTU). These are only suggested applications and cannot assure compliance with all local codes. Please check local electrical codes before starting any electrical project.
6. Bussmann CB185-50 CB185 Series Automotive Circuit Breaker (Plug In Mounting, 50 Amps, Blade Terminal Connection)
Feature
- Type III switchable, waterproof, flush mount manual reset circuit breakers with 1⁄4-28 threaded stud terminals with SEMS nuts installed, and black reset lever
- High amp circuit breakers are typically used in auxiliary and accessory circuits for trucks, buses, RV’s and marine applications
- All high amp circuit breakers comply with the SAE J1117 standard for ignition protection
- All high amp circuit breakers also have applications in battery charging systems that use battery isolators to manage and protect batteries in multi-battery installations
Description
Type III switchable, waterproof, flush mount manual reset circuit breakers with 1⁄4-28 threaded stud terminals with SEMS nuts installed, and black reset lever. High amp circuit breakers are typically used in auxiliary and accessory circuits for trucks, buses, RV’s and marine applications. All high amp circuit breakers comply with the SAE J1117 standard for ignition protection and have applications in battery charging systems that use battery isolators to manage and protect batteries in multi-battery installations.
7. Eaton Corporation CL250CS Double Pole Ul Classified Replacement Breaker, 240V, 50-Amp
Description
50 Amp rating, 240 Volt. UL listed for GE, Siemens, Crouse-Hinds, Murray, T&B & Square D Homeline Panels. Amp Rating: 50A 240 Volt Double pole UL listed for GE, Siemens, Crouse-Hinds, Murray, T&B & Square D Homeline Panels Clamshell.
Conclusion
By our suggestions above, we hope that you can found 50 Amp Acfi Breaker 220 Ge for you.Please don’t forget to share your experience by comment in this post. Thank you!